Weather Proofing

Inside Closure

Fits Tuff-Rib profile Used under Tuff-Rib panels at the eaves.
Used to seal the gap under the panel

Outside Closure

Fits Tuff-Rib profile Used on top of the Tuff-Rib panels (Under the ridge cap, end wall, and transitions)
This seals against unwanted wind and rain

Vented Outside Closure

Installed at the ridge and allows air flow while creating a barrier against rain, insects, and debris.
This seals against unwanted wind and rain

Inside Closure R-Panel

Used under R-Panels at the eaves. This seals the gaps between the ribs of the panels and the decking.
Used to seal the gap under the panel

Outside Closure R-Panel

Used on top of the R-Panel (Under the ridge cap, end wall, and transitions). This seals the gap between the ribs and flashing.

Inside Closure 5v

Used under 5v at the eaves.
Used to seal the gap under the panel

Outside Closure 5V

Used on top of the 5v (Under the ridge cap, end wall, and transitions).
This seals against unwanted wind and rain

Snow Guards

Used to protect against snow slides on the roof.

Univent

This material is used at the ridge to allow venting of the ridge cap while keeping water and debris from penetrating into the structure.

Uniseal

Uniseal is used on to seal the gap at hips, transitions, and other gaps between the metal and flashings when a closure will not suffice.

Sealer Tape

Used for sealing between panel seams and for sealing around flashing.3/8″ Wide x 3/32″ Thick x 45′ Long
1″ Wide x 3/32″ Thick x 50′ Long
2 1/2″ Wide x 3/16″ Thick x 20′ Long

Expanding Foam

Contains an adhesive backing and expands to seal gaps between flashing and panels.

Double Sided Tape

For use under insulation.

Flashers

Flasher

Used to flash around pipes which protrude through the roof . These can only be used where temperatures do not exceed 250 degrees Fahrenheit.

Flasher Table

Retrofit

Retrofit flashers are used when a standard flasher can’t be used such as when power is connected to a pipe or the pipe has a cap.

High Temp Flasher

Used to flash around pipes which protrude through the roof where heat is a concern. The high temp flashers can only be used where temperatures do not exceed 350 degrees Fahrenheit.

Flasher Table

Underlayments And Insulation

R-Foil On Vinyl

The white vinyl can be used when the insulation will be exposed to the interior of the building and a white finish is desired.

R-Foil On Foil

Reflective foil insulation consists of a barrier and reflective foil insulation designed for heated and unheated commercial and agricultural buildings.

Titanium UDL 25 Year

15 mils thick. Patented Sure-Foot technology. Up to 6 months UV exposure. 25 year limited warranty. Size – 48″ x 250′

Titanium UDL 30 Year

15 mils thick. Patented Sure-Foot technology. Up to 6 months UV exposure. 30 year limited warranty. Size – 48″ x 250′

15 lb Felt

Standard 15# felt.

30 lb Felt

Standard 30# felt.

Solar Guard

Post frame building reflective Insulation greatly increases comfort in residential and commercial applications by reducing radiant heat gain.

Valuelock

Synthetic is more cost effective than traditional felt-paper Cost. It is also less prone to be displaced with wind, has better UV resistance and durability and comes with a 6 months exposure rating.

Drip Stop

Drip Stop is a cost effective anti-condensation membrane for preventing dripping caused by condensation. It is factory applied to the back of the panel which saves time and labor costs as well.

Storm Guard

Length: 66.7′ (20.33 m) Width: 36″ (0.9 m), Coverage Per Square: 2 Sq. Per Square, Area: 200 Sq. Ft. (18.58 Sq. m), Storm Guard is also known as ice and water shield and creates a great barrier between metal and decking.

Vinyl Tape

Seams vinyl insulation.

Double Sided Tape

For use under insulation.

Foil Tape

Seams foil insulation.