Trim

Trim can be made to your specifications. Call us for details.

Item Length Girth Gauge Description
Ridge Cap
10’ 0″ -21′ 0″ 13 5/8″ 29
26
Standard pitch is 3/12. Please specify pitches greater than 3/12
Flat Ridge Cap   10’ 0” – 21′ 0″
Variable 29
26
(A) Specify pitch of roof
(B) Specify Length of each leg
Formed Ridge Cap
(For R-Panel Only)
         S_FormedRidge_White.JPG
36″
39″ (Coverage is 36″) 26
Used to cap ridge for low pitch metal buildigs
Small Corner
10’ 0” – 21′ 0″
9 1/4″ 29
26
Used at corner connections or on the rake of building
 Standard Rake/Corner
10’ 0” – 21′ 0″
12 1/8″ 29
26
Used at corner connections or on the rake of building
Inside Corner
10’ 0” – 21′ 0″
12 1/8″ 29
26
Used to trim inside corner connection of building
Rake/Corner (R-Panel)
10’ 0” – 21′ 0″
14″ 29
26
Used at corner connections or on the rake of building when using R-Panel
3 x 3 Angle
10’ 0” – 21′ 0″
7″ 29
26
Used to trim corners or connections
Gable Trim
10’ 0” – 21′ 0″
10 1/4″ 29
26
Used to trim gable ends and provides a drip edge away from the fascia
Standard Eave
10’ 0” – 21′ 0″
4 1/2″ 29
26
Commonly known as drip edge. Can be used around the perimeter of the building
J-Trim
10’ 0”
3 5/8″ 29
26
Used to trim around openings such as windows and doors
J-Trim (R-Panel)
10’ 0” – 21′ 0″
4 1/2″ 29
26
Used to trim around openings such as windows and doors when using R-Panel
Base Angle
10’ 0” – 21′ 0″
4 1/2″ 29
26
Also known as rat guards. Used to keep rodents from entering the building from under wall panels
Double Angle
10’ 0” – 21′ 0″
4″ 29
26
Also known as S trim. Used for veritical panel to panel connections
Door Jamb
10’ 0” – 21′ 0″
6 7/8″ 29
26
Used to trim out door jambs
End Wall
10’ 0” – 21′ 0″
12″ 29
26
Used to flash wall to roof connections. Please specify roof pitch
Side Wall
10’ 0” – 21′ 0″
12″ 29
26
Used to flash wall to roof connections. Standard degree is 90. Please specify pitch if this varies
Transition
10’ 0” – 21′ 0″
12″ 29
26
Used to flash transitions from roof to roof when pitch changes. Please specify both roof pitches
“V” Valley
   10’ 0” – 21′ 0″
20″ 29
26
Standard valley with wings for flashing valleys at roof connections
“W” Valley
W-Valley 20"  10’ 0” – 21′ 0″
20″ 29
26
Valley with center rib to slow velocity of water entering valley
Track Cover
10’ 0” – 21′ 0″
12″ 29
26
Covers and flashes sliding doors and track
Mansard Cap
10’ 0” – 21′ 0″
Variable 29
26
24
Caps over masard or parapet wall. (A) Specify length of each leg (B) Specify width of top
Flat Flashing
        S_FlatSheet_White.JPG
10’ 0” – 21′ 0″
Please Specify
29
26
Available from 1” – 40 7/8” for 29 gauge
Available from 1” – 41 9/16” for 26 gauge
Avaliable from 1″ – 48″ for 24 gauge