1 1/2″ Mechanical Lock Trim

1 1/2″ Mechanical Lock Trim can be made to your specifications. Call us for
details.

Item Length Girth Gauge Description
ridge cap
Ridge

10′-21′

13 6/8″

26
24

Used to cap the intersections of a roof at the peak. Can be used for gable or hip roofs.
Hip
Hip

10′-21′

10″

26
24

Used at hip connections of a roof when something smaller than a ridge cap is desired as in smaller structures. 
Valley
Valley

10′-21′

20″

26
24

Used to flash valley connection.The valley lip helps to divert water if it reaches the top of the valley.
W Valley
W Valley

10′-21′

20″

26
24

Used to flash valley connections. The center rib helps slow the velocity of water entering the valley.
W Valley w/wings
W Valley w/wings

10′-21′

20″

26
24

Gives maximum protection in a valley of a roof. The center ridge slows down the velocity of the water while the upper wing keeps water from getting past the top of the valley.
Zee Closure
Zee Closure

10′-21′

N/A

26
24

Zees are used in conjunction with ridge, hip, rake, end wall, side wall, and high side trims to give them something to fasten to on top of the panel.
Valley Cleat
Valley Cleat

10′-21′

4″

26
24

This cleat is used to hold valleys in place under the panels.
Starter Trim
Starter Trim

10′-21′

4 1/2″

26
24

Can be used at the bottom of the panel to secure the panel to the decking.
Offset Plate
Offset Plate

10′-21′

3 1/2″

26
24

When an extended eave is not used at the eave this can be used to fasten to the decking and hem the panel to.
Perimiter Cleat
Perimeter Cleat

10′-21′

2″

26
24

This is used in conjunction with rake, eave, high side, and parapet caps to prevent the use of thru fastened screws.
Eave
Eave

10′-21′

8 1/8″

26
24

Used at the eave of the building to flash the facia and to help protect against water that comes from the end of the panel.
Rake
Rake

10′-21′

9 1/2″

26
24

Installed at the gable end of a structure to help hold down the panel as well as prevent water from blowing under the roof panels at the gable end.
Endwall
Endwall

10′-21′

10″

26
24

Flashes the area between the wall and the panel where the panel runs perpendicular to the wall. Please specify the pitch of the
Sidewall
Sidewall

10′-21′

10″

26
24

Flashes the area between the wall and the panel where the panel horizontal to the wall.
transition
Transition

10′-21′

12″

26
24

Used where two roofs meet to flash the changes in pitch such as a where a porch connects to a main roof.
Extended Eave
Extended Eave

10′-21′

8″

26
24

Used at the eave of the structure and features a projection for panel support as well as something to hem the panel to.
High Side Trim
High Side Trim

10′-21′

10″

26
24

Used at the top of a shed type roof to keep water from blowing in underneath the panels.
Fascia Trim
Fascia Trim

10′-21′

N/A

26
24

Used to apply to the fascia board for cosmetic reasons as well as to protect against water.